Five-Year Clinical Outcomes After XIENCE PRIME Everolimus Elution Coronary Stent System (EECSS) Implantation

Announcing a new article publication for Cardiovascular Innovations and Applications journal. This study was aimed at evaluating 5-year effectiveness and safety in participants after XIENCE PRIME Everolimus Elution Coronary Stent System (EECSS) implantation.

From December 2013 to May 2014, 108 patients (127 lesions) were treated with the XIENCE PRIME EECSS. The entire follow-up included annual assessments for 5 years after treatment or until one of the clinical endpoints was reached. We evaluated the 5-year clinical outcomes with Kaplan-Meier analysis and the Cox regression model.

Nearly three-quarters of the participants were men (76.8%), and the average age was 65.6 ± 10.8 years. Bifurcation lesions accounted for 96.1% (122 lesions), and left main lesions accounted for 3.9% (five lesions), with a total count of 127 lesions. The cumulative rate of major adverse cardiac events was as follows: 1 year, 1.9%; 2 year, 4.0%; and 5 year, 10.0%. No definite or probable stent thrombosis was observed, and the rate of target lesion failure was only 3.3% over 5 years. The cumulative rate of major bleeding eventually increased to only 4.4%.

The 5-year clinical outcomes were favorable in patients treated with XIENCE PRIME EECSS, and the incidence of stent thrombosis and target lesion failure was relatively low. The incidence of major bleeding gradually increased but remained moderate.

https://www.scienceopen.com/hosted-document?doi=10.15212/CVIA.2023.0013

CVIA is available on the ScienceOpen platform and at Cardiovascular Innovations and Applications. Submissions may be made using ScholarOne Manuscripts. There are no author submission or article processing fees. Cardiovascular Innovations and Applications is indexed in the EMBASE, EBSCO, ESCI, OCLC, Primo Central (Ex Libris), Sherpa Romeo, NISC (National Information Services Corporation), DOAJ, Index Copernicus, Research4Life and Ulrich’s web Databases. Follow CVIA on Twitter @CVIA_Journal; or Facebook.

Rongrong Shen, Peiyu Zhang and Jing Liu et al. Five-Year Clinical Outcomes After XIENCE PRIME Everolimus Elution Coronary Stent System (EECSS) Implantation. CVIA. 2023. Vol. 8(1). DOI: 10.15212/CVIA.2023.0013

Loading